BJ series hotel tank activation disinfection of water purification equipment

Date:

2024-08-05 16:19

Introduction

Shanghai SCIYEE Water Sci. & Tech. CO., LTD (hereinafter referred to as "the science and technology") introduced the innovative BJ series hotel tank activation water purification equipment, disinfection equipment adopts new type of high efficiency, resistance to oxidation and anti pollution electrodes, can be directly to deal with low TDS waters, without adding any chemical products. It can effectively control the growth of algae, bacteria and Legionella in the water. At the same time, it can produce weak alkaline reducing water to neutralize free radicals in the human body.
BJ system equipment is easy to operate, fully automatic operation, remote monitoring through GPRS Control equipment running status, prompt alarm information. The application of cutting-edge electrolysis technology and electrodes, completely solved the cleaning problem of electrode scaling in long operation, there is no need for electrode cleaning during the electrode life cycle.

Sterilization principle

(1)Electric field intensity and electron sterilization directly
The micro-electrolysis reaction of water occurs on the electrode of the water treatment system, so that the electric field strength in water is much greater than the 130V/m that microorganisms can adapt to, which accelerates their physiological metabolism and promotes the withered of bacteria.
Through the high-speed movement of electrons, it impacts the bacterial cell membrane, destroys its ion channels, and causes its death, so as to achieve the purpose of sterilization. 
(2)Produce strong oxidative active substances and sustainable sterilization
 Micro electrolysis in water can produce reactive oxygen species, H2O2, OH, with strong 

oxidizing active substances, such as can damage the cell membrane and penetration into the cell, destroy organic chain structure, so that the microbial death.

When Cl- is contained in water, in addition to the microelectrolytic reaction, the anode and cathode will also react as follows:

Anode reaction:

Cathode reaction:

(Mn+ is either a metal ion or a hydrogen ion,M for metal or hydrogen)

    The chlorine gas, hypochlorite, etc. produced by the electrochemical oxidation process can be effectively and continuously sterilized.

Advantages and Features

1.Convenient selection, modular system design, convenient for customer management and use;
2.Direct electrolysis of raw water, without the use of other chemical agents, safe, low operating costs;
3.New patented electrode, high current efficiency; And can adapt to broad TDS water quality to ensure longevity;
4.Advanced electrolysis technology, no need for electrode pickling, easy to break the conventional electrolysis scaling, need to clean the cumbersome operation, convenient, environmental protection;
5.Can produce reactive oxygen species and other strong oxidizing substances, control algae, good sterilization effect;


6.Automatic operation, can output alarm information through GPRS, remote monitoring;
7.The equipment is equipped with conductivity, temperature, flow and other alarm Settings to ensure the stable operation of the equipment;
8.device combined with water purification system, will again after purification of water disinfection, ensure that the water in the water tank meet water quality requirements;
9.Water after the equipment electrolysis, can produce small molecular mass water (weak alkaline reducing water) and human free radicals, activate human cells。

 

Technical Parameters

The input power

Stress at work

Applicable water temperature

Scope of TDS

220V、50/60Hz

0.2~0.4MPa

0~50℃

50~5000mg/L

Rate of sterilization

Algae elimination rate

legionella

Single body size

≥99%

≥99%

In line with international standards

See selection guide

 Applications

 

☆ Domestic and drinking water                   ☆  Secondary water supply tank, pool  

(The calculated amount of available chlorine was 0.3~0.5mg/L)

(The calculated amount of available chlorine was 0.3~0.5mg/L)

                      

 ☆  Swimming pool water                              ☆ Freshwater park water treatment          
(Reference for selection of available chlorine computation 0.2 ~ 1 mg/L)             (Reference to selection of available chlorine computation 0.05 ~ 0.3 mg/L)

 

Model Selection Guide


TDS

The model and power

Flow rate

interface

Dimensions of equipment

Equipment weight

 

TDS

100mg/L

TDS

200 mg/L

TDS

300 mg/L

m3/h

DN

LXWXH (m)

kg

10

BJ-10-100

1.10kW

BJ-10-200

0.90kW

BJ-10-300

0.80kW

2

DN25

2.0x1.0x2.5

1500

20

BJ-20-100

2.10kW

BJ-20-200

1.30kW

BJ-20-300

0.80kW

2

DN25

2.0x1.0x2.5

2000

30

BJ-30-100

2.80kW

BJ-30-200

1.90kW

BJ-30-300

1.30kW

3

DN32

2.2x1.0x2.5

2500

50

BJ-50-100

3.90kW

BJ-50-200

2.30kW

BJ-50-300

1.60kW

4

DN32

2.2x1.0x2.5

3000

100

BJ-100-100

7.30kW

BJ-100-200

4.10kW

BJ-100-300

2.80kW

6

DN40

2.5x1.5x2.5

3500  

 

Note: the device size should be according to the judgment of TDS of water quality and selection. The power is different under different water quality conditions.   

Device contains a single power supply pump required power; The equipment size does not include the floor area of the water supply pump;